Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9008532

- Product Categories
- Friendly Links
Information Name: | Vortex steam flow meter, gas vortex flowmeter, vortex flowmeter principle |
Published: | 2013-04-03 |
Validity: | 500 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | The the steam flowmeter Overview: Smart Vortex Flowmeter Series steam flow meter Karman vortex street principle manufacturing, with high accuracy, wide range, low power consumption, easy installation, simple operation, small pressure loss, and free on-site commissioning, The ideal steam metering instrumentation, steam flow measurement system with no moving parts, stable performance for vibration environment for high-temperature impact resistance and are not afraid of steam hammer phenomenon with temperature and pressure compensation, high accuracy. Steam flow meter main technical parameters: maximum medium temperature: 250 ° C (special manufacture up to 350 ° C). Maximum operating pressure: 1.6MPa ~ 16MPa. Accuracy: 1.0, 1.5. Explosion levels: ExdIIBT4. Protection class: IP65. Ambient temperature: -40 ℃ ~ +55 ℃. Specifications: 1, screw type, card-mounted, flange type: DN10 ~ DN50. 2, card-mounted, flange type: DN65 ~ DN300. 3, the plug-in: DN350 ~ DN1000. Steam Vortex Flowmeter Selection Guide: according to the structural features of the intelligent vortex flowmeter series of steam flow meter, classified as one and split two. Integrated measurement of saturated steam, set a vortex flow sensor, temperature sensor (pressure sensor) and display instrument has a the intelligent temperature (or pressure) compensation function comes 3.6V high-energy battery or 24VDC (usually a pulse signal output, two-wire 4 to 20mADC output or RS485 communication using) power supply, place the LCD medium temperature (℃) [or working pressure (MPa)], the instantaneous mass flow rate (Kg / h) and cumulative mass flow (Kg) . Integrated measurement of superheated steam, set the vortex flow sensors, temperature sensors, pressure sensors, and display instrument in one smart temperature and pressure compensation function comes 3.6V high-energy battery or 24VDC (usually pulse signal output, two-wire 4 ~ 20mADC output or RS485 communication) powered situ LCD medium temperature (℃), working pressure (MPa), the instantaneous mass flow rate (Kg / h) and cumulative mass flow rate (Kg). The split measuring saturated steam, by Vortex vapor flow sensor, temperature sensor (pressure sensor) and intelligent traffic totalizer consists of three parts, with the the intelligent temperature (or pressure) compensation function displayed by the intelligent flow totalizer remote medium temperature (℃) [or working pressure (MPa)], the instantaneous mass flow rate (Kg / h) and cumulative mass flow (Kg). Split measurement of superheated steam, by the vortex flow sensors, temperature sensors, pressure sensors, and intelligent traffic Totalizer four parts, with intelligent temperature and pressure compensation function displayed by the intelligent flow totalizer remote display medium temperature (℃ ), working pressure (MPa), the instantaneous mass flow rate (Kg / h) and cumulative mass flow (Kg). Needs to be noted, when only requires measuring the volumetric flow rate of the working conditions (which is defined as the simple matching is usually applied to the the basic medium temperature and pressure constant occasions), either integrated or split shall smart temperature and pressure compensation function, the configuration of the temperature and pressure sensors, show only transient conditions the volume flow rate (m3 / h) and cumulative conditions volume flow (m3). Applications: All steam production and use of the site. Volume flow measuring range: In order to facilitate selection, we will steam conditions simply defined as the volume flow (actual medium temperature and under the working pressure) in the working condition. Specifications Measuring range of volume flow measurement range of conditions, DN10 1 ~~ 3m3 / h DN15 2.5 ~~ 10m3 / h DN20 capacity of 25m3 / h DN25 9 ~~ 45m3 / h DN32 15 ~~ 105m3 / h DN40 20 ~~ 200m3 / h DN50 35 ~~ 350m3 / h DN65 60 ~ 600m3 / h DN80 90 ~ 900m3 / h DN100 140 ~ 1400m3 / h DN125 220 ~ 2200m3 / h DN150 250 ~ 2500m3 / h DN200 440 ~ 4400m3 / h DN250 720 ~ 7200m3 / h DN300 1000 ~ 10000m3 / h Note : DN350 ~ DN1000 volume flow measurement range of specification conditions and other relevant content, please refer to the product's "manual." |
Admin>>>
You are the 10925 visitor
Copyright © GuangDong ICP No. 10089450, Tianjin strong Fisher Scientific Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10925 visitor
Copyright © GuangDong ICP No. 10089450, Tianjin strong Fisher Scientific Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility